Authorised Distributors for :
 
medicon Fisher and Paykel ResMed Fanem Airsep Oxygen Concentrators Zoll Maquet
 
Welcome to Visakha Healthcare India Pvt Ltd

Patient Monitoring Cables and Accessories

 

Nellcor™ Forehead SpO2 Sensor

Offers significant advancement in patient safety monitoring. Nellcor™ forehead SpO2 sensor provides an effective monitoring option when digit sensors fail to obtain an SpO2 signal1,2 and detects changes in SpO2 notably earlier than digit sensors during poor perfusion conditions.3,4

  • Branson R, Davis B, Davis K et al. Comparison of forehead and finger oximetry in mechanically ventilated patients with poor perfusion. Respir Care. 2003;48:1086.
  • Schallom, Sona, McSweeney, Mazuski. Comparison of reflective and transmission oximetry in surgical/trauma patients with poor perfusion. Crit Care Med. 2005;32:S138.
  • Bebout DE, Mannheimer PD, Wun C-C. Site-dependent differences in the time to detect changes in saturation during low perfusion. Crit Care Med. 2001;29(12)A115.
  • MacLeod DB, Cortinez LI, Keifer JC et al. The desaturation response time of finger pulse oximeters during mild hypothermia. Anaesthesia. 2005;60:65-71.
   
Nellcor™ SpO2 sensors (Adhesive)
Highly accurate and feature tear-resistant bandages that provide a comfortable, secure "second-skin" fit. The Nellcor™ SpO2 sensor bandage is designed to prevent ambient light from interfering with SpO2 readings.
   
Nellcor™ SpO2 sensors non-adhesive
For patients with sensitive skin, applying and removing adhesives can damage the delicate epidermal tissue and may disrupt the skin’s normal barrier function, leading to increased risk of infection.1 These sensors give clinicians a gentle alternative to adhesive sensors for patients with fragile skin. Ideal for monitoring neonates and preterm infants, geriatric and burn patients, or other patients with sensitive skin.

Nellcor™ SpO2 sensors non-adhesive come in three models: preterm infants weighing < 1.5 kg, neonatal patients weighing 1.5 to 5 kg and adult patients weighing > 40 kg.

1. Lund CH, Kuller J, Lane AT, Lott JW Raines DA, Thomas KK. Neonatal skin care: evaluation of the AWHONN/NANN research-based practice project on knowledge and skin care practices. Association of Women's Health, Obstetric and Neonatal Nurses/National Association of Neonatal Nurses. J Obstet Gynecol Neonatal Nurs. 2001;30(1):30-40.

   
Nellcor™ SpO2 Sensors Two Piece with OxiMax™ Technology
Reusable cable with a sterile, single patient use adhesive bandage to form a cost effective sensor. Nellcor™ SpO2 sensors two piece with OxiMax™ technology work with the current Nellcor™ pulse oximetry monitors with OxiMax™ technology as well as previous generations.
   
Nellcor™ Reusable sensors with OxiMax™ technology
Reusable sensor options for spot checks or short-term monitoring. From a multi-site sensor to a convenient clip design, Covidien assures the quality and durability of the Nellcor™ reusable sensors with OxiMax™ technology. All of the reusable sensors work with the current Nellcor™ pulse oximetry monitors with OxiMax™ technology as well as previous generations.
   
CALL NOW AT: +91 9246646561